Resource Type

Journal Article 3

Year

2012 1

2008 1

2000 1

Keywords

LC/MS/MS 1

OCT2 1

atomic energy science and technology 1

catalpol 1

cyclotron 1

positron emission tomography 1

preparation technique and application 1

proton beam therapy 1

radioisotope 1

short life radioisotope 1

open ︾

Search scope:

排序: Display mode:

LC/MS/MS and radioisotope method combined for recognizing the affinity between catalpol and OCT2 transporter

Zhiyu ZHANG, Changxiao LIU, Duanyun SI, Rong LU, Xiulin YI

Frontiers of Chemical Science and Engineering 2012, Volume 6, Issue 4,   Pages 436-442 doi: 10.1007/s11705-012-1222-4

Abstract: In this paper, chromatography/tandem mass spectrometry (LC/MS/MS) combined with radioisotope method was

Keywords: catalpol     LC/MS/MS     OCT2    

Radioisotope Technique and Its Application Progress in China

Zhang Jinrong,Luo Zhifu

Strategic Study of CAE 2008, Volume 10, Issue 1,   Pages 61-69

Abstract:

The paper introduces the inception of radioisotope and its applicationthe research and development,production, application progress and the future development prospect of radioisotope

Keywords: atomic energy science and technology     radioisotope     preparation technique and application    

Medical Cyclotron Used for Diagnostic or Therapy

Fan Mingwu

Strategic Study of CAE 2000, Volume 2, Issue 12,   Pages 9-15

Abstract:

Cyclotron operated within a hospital to deliver radiation to produce short life radioactive isotopes for diagnostic purpose is used in many hospitals. But cyclotron used for proton therapy is just at beginning. Proton beam therapy is a technologically advanced approach since it achieves precise radiation dose distribution. As the depth of penetration is a function of its energy, the point of energy release of the proton can be very precisely determined. The path of the proton beam is linear and causes very little secondary lateral scatter. Healthy tissues upstream from the tumor receive only a small dose and those located around the tumor and behind receive virtually none. Thus proton beam therapy is the most effective method. On the other hand, the cyclotron must be reliable, and the beam must be stable to ensure patient´s safety since the proton beam is used directly. Efficiency of beam delivery to the treatment rooms, raster scanning techniques to ensure the correct control of beam energy, intensity, and position stability, rapid and precise flexibility in changing beam parameter are also essential for satisfying clinical needs. The design efforts for developing a hsopital-based medical therapy cyclotron including the clinical beam delivery systems and integrated control system are really complex, and are less well developed than patients real need. A conception scheme for the purpose is proposed.

Keywords: cyclotron     positron emission tomography     short life radioisotope     proton beam therapy    

Title Author Date Type Operation

LC/MS/MS and radioisotope method combined for recognizing the affinity between catalpol and OCT2 transporter

Zhiyu ZHANG, Changxiao LIU, Duanyun SI, Rong LU, Xiulin YI

Journal Article

Radioisotope Technique and Its Application Progress in China

Zhang Jinrong,Luo Zhifu

Journal Article

Medical Cyclotron Used for Diagnostic or Therapy

Fan Mingwu

Journal Article